S7 – Start upload

The rule is related to Siemens S7 communication protocol, which is used for communication with Siemens PLCs. Each command serves a specific purpose in interacting with the PLC. "S7 - Start upload" command signals the beginning of an upload process from the PLC. It prepares the PLC to send specific data (e.g., program code, configuration) to the client (e.g., programming tool) during the upload.

Categories:

ID Number

4000030

Signature

alert tcp any any -> any 102 (msg:"S7 - Start upload";content:"|03 00|";offset:0;depth:2;content:"|32 01|";offset:7;depth:2;content:"|1d|";offset:17;depth:1;sid:4000030;)

MITRE ATT&CK Technique

-

Severity

Low

Recommendations/Investigative actions

Authorize the connection. If the connection was approved as a network engineer accessing the PLC - archive and baseline the rule. If not - check the connection and investigate the relevant IP address.