S7 – Upload

The rule is related to Siemens S7 communication protocol, which is used for communication with Siemens PLCs. Each command serves a specific purpose in interacting with the PLC. "S7 - Upload" command is used to transfer data from the PLC to the client as part of an upload process. This could include PLC program code, data blocks, or other configurations.

Categories:

ID Number

4000031

Signature

alert tcp any any -> any 102 (msg:"S7 - Upload";content:"|03 00|";offset:0;depth:2;content:"|32 01|";offset:7;depth:2;content:"|1e|";offset:17;depth:1;sid:4000031;)

MITRE ATT&CK Technique

-

Severity

Low

Recommendations/Investigative actions

Authorize the connection. If the connection was approved as a network engineer accessing the PLC - archive and baseline the rule. If not - check the connection and investigate the relevant IP address.